 110 Watts
LPS110 Series
Total Power: 80-110 Watts Input Voltage: 85-264 VAC 120-300 VDC # of Outputs: Single
Electrical Specs
Input
Input range Frequency Inrush current 85-264 VAC 120-300 VDC 47-440 Hz <18 A peak @ 115 VAC; <36 A peak @ 230 VAC, cold start @ 25C 2.5 A max. (RMS) @ 115 VAC 70% typical at full load FCC Class B conducted CISPR 22 Class B conducted EN55022 Class B conducted VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC-input 80 W for convection; 110 W with 30 CFM forced air 5% minimum 20 ms @80 W load, 115 VAC nominal line Short circuit protection. Case overload protected @ 110-145% above peak rating 5 V output: 5.7-6.7 VDC. Other outputs 10% to 20% above nominal output. Latching type, recycle AC to reset. TTL logic signal goes high 50-150 msec after main output. It goes low at least 4 msec before loss of regulation. Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
Input current Efficiency EMI filter
Special Features
* * * * * * * * * * * Universal input High efficiency Remote sense Built-in EMI filter Low output ripple Adjustable output Power fail Overvoltage protection Overload protection Optional L bracket (-B suffix) Cover kit available LPX110-C
Safety ground leakage current
Output
Maximum power Adjustment range Hold-up time Overload protection
Overvoltage protection
Environmental
Operating temperature: 0 to 50C ambient derate each output at 2.5% per degree from 50 to 70C Electromagnetic susceptibility: Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity: Operating; non-condensing 5% to 95% Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational Storage temperature: -40 to 85C Temperature coefficient: .04% per C MTBF demonstrated: >550,000 hours at full load and 25C ambient conditions
Logic Control
Power failure
Remote sense
Safety
VDE UL CSA NEMKO CB CE 0805/EN60950 (IEC950) UL1950 CSA 22.2-234 Level 3 EN 60950/EMKO-TUE (74-sec) 203 Certificate and report Mark (LVD) 11774-3336-1245 (LC #84997) E132002 LR53982C P95100376 1563, 1564, 1565, 1566, 1567
100
Technical Support: (888) 41-ASTEC or (407) 241-2752 Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
rev 12.10.03
AMERICAS 5810 Van Allen Way Carlsbad, CA 92008 Telephone: 760-930-4600 Facsimile: 760-930-0698
EUROPE Astec House, Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX, UK Telephone: 44 (1384) 842-211 Facsimile: 44 (1384) 843-355
ASIA Units 2111-2116, Level 21 Tower1, Metroplaza 223, Hing Fong Road Fwai Fong, New Territories Hong Kong Telephone: 852-2437-9662 Facsimile: 852-2402-4426
LPS110 Series
Ordering Information
Model Number LPS113 LPS114 LPS115 LPS118 Output Voltage 12 V 15 V 24 V 48 V Minimum Load 0A 0A 0A 0A Maximum Load with Convection Cooling 6.7 A 5.3 A 3.3 A 1.7 A Maximum Load with 30 CFM Forced Air 9.2 A 7.3 A 4.6 A 2.3 A Peak Load1 10.4 A 8.3 A 5.2 A 2.6 A Regulation2 Ripple P/P (PARD)3 120 mV 150 mV 240 mV 480 mV
2% 2% 2% 2%
1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor at rated line voltage and load. Note: -B suffix added to model number indicates L bracket option.
-B Bracket
Pin Assignments
ConnectorLPS113 SK1-1 SK1-3 SK1-5 SK2-1 SK2-2 SK2-3 SK2-4 SK2-5 SK2-6 SK2-7 SK2-8 SK2-9 SK201-1 SK201-2 SK202-1 SK202-2 GND Neutral Line +12 V +12 V +12 V Common Common Common Common +12 V +12 V +sense -sense Pok GND LPS114 GND Neutral Line +15 V +15 V +15 V Common Common Common Common +15 V +15 V +sense -sense Pok GND LPS115 GND Neutral Line +24 V +24 V +24 V Common Common Common Common +24 V +24 V +sense -sense Pok GND LPS118 GND Neutral Line +48 V +48 V +48 V Common Common Common Common +48 V +48 V +sense -sense Pok GND
4.28" (108.6) 2.5" (63.5) #6-32 PEM 6 places
6.4" (162.6)
7.3" (185.5)
2.2" (56) 0.86" (21.8) 5.9" (150.0)
Mating Connectors AC Input: Molex 09-50-8051 (USA) 09-91-0500 (UK) PINS: 08-58-0111 Molex 09-50-8091 (USA) 09-91-0900 (UK) PINS: 08-58-0111 Remote sense/power fail: Molex 22-01-1022 (USA) 22-01-1023 (UK) PINS: 08-50-0114 Astec Connector Kit #70-841-007, includes all of the above Notes: 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is .02". 3. Specifications are for convection rating at factory settings unless otherwise stated. 4. Mounting holes M1 and M2 should be grounded for EMI purposes. 5. Mounting hole M1 is safety ground connection. 6. L Bracket mounting (6-32) maximum insertion depth is .20" (5). 7. Warranty: 1 year 8. Weight: 1.25 lb / 0.57 kg DC Outputs:
4.0" (101.6)
0.25" (6.35) M2
1 2 3 4 5 6 7 8 9 SK 201 (+S) 1 (-S) 2
SK 202 (POK) 12
VOLTAGE ADJ
3.5" (88.9) 1 3
SK 1
GND N L M1 0.156" (4) DIA (4 places)
0.25" (6.35)
6.5" (165.1)
7.0" (177.8)
1.80" (45.7)
0.12" (3)
www.astecpower.com
SK 2
101


▲Up To Search▲   

 
Price & Availability of LPS110

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X